IS 15658:2021 - Precast Concrete Blocks for Paving
Key technical information and requirements related to Paver Blocks from IS 15658:2021.
IS 15658: 2021 PRECAST CONCRETE BLOCKS FOR PAVING — SPECIFICATION (Key Information)
RECOMMENDED GRADES OF PAVER BLOCKS FOR DIFFERENT TRAFFIC CATEGORIES
# Grade
Designation
Compressive
Strength at
28 days, fck
MPa
Traffic
Category
Minimum
Thickness
mm
Traffic Examples of Application
1 M-30 30 Non-traffic 50 Building premises, monument premises, landscapes, public
gardens/parks, domestic drives, paths and patios,
embankment slopes, sand stabilization area, etc.
2 M-35 35 Light traffic 60 Pedestrian plazas, shopping complexes ramps, car parks, office
driveways, housing colonies, office complexes, rural roads with
low volume traffic, farmhouses, beach sites, tourist resorts ,
local authority footways, residential roads, etc.
3 M-40 40 Medium
traffic
80 City streets, small and medium market roads, low volume
roads, utility cuts on arterial roads, etc.
4 M-50 50 Heavy
traffic
100 Bus terminals, industrial complexes, mandi houses, roads on
expansive soils, factory floor, service stations, industrial
pavements, etc.
5 M-55 55 Very Heavy
Traffic
100 Container terminals, ports, docks yards, mine access roads,
bulk cargo handling areas, airport pavements, etc.
RECOMMENDED DIMENSIONS & TOLERANCES FOR PAVER BLOCKS
# Dimension Recommended Values Tolerance Limit for Paver Block
Thickness < 100 mm Thickness ≥ 100 mm
1 Width - +/- 2 mm +/- 3 mm
2 Length - +/- 2 mm +/- 3 mm
3 Thickness 50-120 mm +/- 3 mm +/- 4 mm
4 Aspect Ratio Max. 4.0
5 Chamfer Min. 5mm, Max. 7mm +/- 1 mm +/- 1mm
6 Squareness Nil +/- 2 mm +/- 3 mm
PHYSICAL REQUIREMENTS:
# Characteristic Individual Average
1 Water Absorption, %, Max 7 6
2 Compressive Strength, MPa, Min
(Value of fck is given in col 3 of Table 1 above)
fck – 3 fck + 0.825 x established standard deviation
(rounded off to nearest 0.5 MPa)
3 Abrasion Resistance, mm3 / 5000 mm2, Max
a) Dry
b) Wet
20,000
22,000
18,000
20,000
4 Tensile Splitting Strength, MPa, Min
• For grades < M 40
• For grades ≥ M 40
0.08 fck
3.0 MPa
0.085 fck
3.6 MPa
5 Flexural Strength, MPa, Min 0.10 fck 0.11 fck
(For further details please refer to the Standard)